Regular price

£249.00

Flexistim IF is a powerful and versatile electrotherapy device that uses Interferential Therapy with a choice of preset programmes and manual settings. It can be used for both, profession and home healthcare environments to treat a variety of cond...
  • SKU:

Order by 3PM for NEXT DAY Delivery

UK only - T&C's apply for more details click here

We accept the following payment methods

master paypal visa klarna
Description

Flexistim IF is a powerful and versatile electrotherapy device that uses Interferential Therapy with a choice of preset programmes and manual settings. It can be used for both, profession and home healthcare environments to treat a variety of conditions using electric impulses.

The Interferential Therapy, or just IF, which is the core of this electrotherapy device is the type of treatment that delivers continuous stimulation deep into tissues. This way it is capable of dealing with deep seated pains. Additionally, Interferential Therapy is used to reduce swelling and inflammation, both of which can sometimes be the source of the pain.

When Flexistim IF is in use, electrical impulses are sent through self-adhesive electrode pads which are placed on the skin around the area of pain. The impulses use IF to combat aches, pains and strains to provide much needed relief when you need it most.

There is a plethora of conditions that could benefit from using Flexistim electrotherapy device. A few to list would be arthritis, joint pain, sciatica, spondylitis, rheumatoid arthritis and osteoarthritis, muscle strains and injuries.

Please see 'User Manuals' for Clinical Applications of the Flexistim IF.

    Warnings and Cautions

    CONTRAINDICATIONS:

    • Do not use this device on patients who have a cardiac pacemaker, implanted defibrillator, or other implanted electronic devices, because this may cause electric shock, burns, electrical interference, or death. Application of electrodes near the thorax may increase the risk of cardiac fibrillation.
    • Do not use this device on patients whose pain syndromes are undiagnosed.
    • Do not apply stimulation over the pregnant uterus.

    WARNINGS:

    • Do not apply stimulation over the neck or mouth because this could cause severe muscle spasms resulting in closure of the airway, difficulty in breathing, or adverse effects on heart rhythm or blood pressure.
    • Do not apply stimulation across the chest, because IFT currents penetrate deep into the tissue and the introduction of electrical current into the chest may cause rhythm disturbances to the patient’s heart, which could be lethal.
    • Do not apply stimulation, other than microcurrent, over open wounds or rashes, or over swollen, red, infected, or inflamed areas or skin eruptions (e.g. phlebitis, thrombophlebitis, varicose veins). 
    • Do not apply stimulation over, or in proximity to, cancerous lesions.
    • Do not apply stimulation in the presence of electronic monitoring equipment (e.g. cardiac monitors, ECG alarms), which may not operate properly when the electrical stimulation device is in use.
    • Do not apply stimulation when in the bath or shower.
    • Do not apply stimulation while driving, operating machinery, or during any activity in which electrical stimulation can put the patient at risk of injury.
    • Consult with your physician before using this device, because the device may cause lethal rhythm disturbances to the heart in susceptible individuals. 
    • Apply stimulation only to normal, intact, clean, healthy skin.
    • Using the device directly over metallic implants could cause the currents to focus over a small area, causing tissue burns. If you have metal implants, do not place the pads near, or across the implant, and adjust the intensity with care.
    • Caution should be observed when using the Flexistim at high strength settings. Prolonged use at high settings may cause muscle injury or tissue inflammation.
    • There are no user serviceable parts. No modification of this equipment is allowed.

    PRECAUTIONS:

    • Since the effects of stimulation of the brain are unknown, stimulation should not be applied across the head and electrodes should not be placed on opposite sides of the head, unless you are in Microcurrent mode.
    • The safety of electrical stimulation during pregnancy has not been established.
    • Some patients may experience skin irritation or hypersensitivity due to the electrical stimulation or electrical conductive medium (gel).
    • Patients with suspected or diagnosed heart disease should follow precautions recommended by their physicians.
    • Patients with suspected or diagnosed epilepsy should follow precautions recommended by their physicians.
    • Use caution when the patient has a tendency to bleed internally, such as following an injury or fracture.
    • Use caution following recent surgical procedures when stimulation may disrupt the patient’s healing process.
    • Use caution if stimulation is applied over areas of skin with less than normal sensitivity.
    • Keep this device out of the reach of children. Long cord - risk of strangulation in infants.
    • Do not permit use by children unable to understand the instructions or persons with cognitive disabilities, i.e.: Alzheimer’s disease or dementia.

    ADVERSE REACTIONS:

    • Patients may experience skin irritation and burns beneath the stimulation electrodes applied to the skin.
    • Patients may experience headache and other painful sensations during or following the application of electrical stimulation near the eyes and to the head and face.
    • Patients should stop using the device and should consult with their physicians if they experience adverse reactions from the device.

    GENERAL WARNINGS:

    • Do not immerse any part of the unit in water 
    • Do not place the unit close to excessive heat.
    • Do not use any electrodes which are less than 50 mm x 50 mm.
    • Use only the specified battery: 1 x 3.7 volt rechargeable lithium battery. The use of any other battery could damage the unit.
    • Remove battery if unit is not used for a long period of time.
    • Do not use the unit while asleep.
    • Do not put the lead wire on, or wrapped around the neck.
    • Use this device only with the leads, electrodes and accessories recommended by the manufacturer. Use of other parts materials supplied by the manufacturer can degrade minimum safety and invalidate the warranty.
    • After inserting plugs into both CH1 and CH2 sockets, please do not remove the plugs when the unit is working. Ensure that the unit is switched OFF before removing the plugs.
    • Keep the unit away from sources of high magnetic fields such as TV’S, microwave ovens and hi-fi speakers, as these may affect the LCD screen.
    • Keep the device away from a fireplace or radiant heater, as the heat may affect the device.
    • Keep the device away from nebulizer or steam kettle, as the moisture may affect the device.
    • Keep the device away from sunlight, as long-term exposure to sunlight may affect the rubber causing it to become less elastic and crack.
    • Keep the device away from lint and dust, as long-term exposure to lint or dust may affect the sockets or cause the battery connector to develop a bad contact. 
    Flexistim IF electrotherapy device is suitable for clinical and home healthcare environments.
    Flexistim IF electrotherapy device provides general pain relief without the need for drugs.
    Flexistim IF electrotherapy device is portable and lightweight.

    Key Features

    3 preset programmes and 3 user defined programmes enabling you to experiment and save your favourite settings;
    Pure sinusoidal carrier wave with constant energy (modified constant current) control and 40mA safety override for home use;
    Portable and lightweight with belt clip included for mobile use;
    Clear, backlit LCD screen for ease of use;
    Removable, rechargeable Li-ion battery for use on-the-go and external mains adaptor for extended use;
    Flexistim IF automatically starts using the programme last used and also has a usage timer which records the total time it has been used, and the number of uses;
    Automatic keypad lock if no button is used for 10 seconds;
    Switching charging adaptor with both UK and EU connections

    What's Included

    1 x Flexistim IF Electrotherapy Unit
    4 x 50x50mm self-adhesive electrodes (CM5050)
    1 x Removable, rechargeable BL-6F Li-ion battery (B-BL6F)
    1 x Battery charging cradle (X-FLEX-CR)
    1 x Switching charging adaptor with a UK (3 pin) and a European (2 pin) mains adaptor plug (X-FLEXIPA)
    2 x Lead wires (L-ST2)
    1 x Instruction manual
    1 x Storage and transport pouch.

    Customer Reviews

    Come and Visit us in-store

    Come visit
    us in-store

    Visit our office in Epsom, Surrey, UK. We would be delighted to welcome you!
    Get Directions

    View our
    catalogue here

    Give a look to all our devices and get a new level on pain relief, muscle toning and beauty enhancers with our clinically back-up units
    Download Catalogue

    Be the first to receive special offers, hear about our exclusive news and new product launches. We give 10% off your first order to every new subscriber. Join the TensCare family today.

    Most Recommended

    Most Recommended

    Most Recommended

    Most Recommended

    Most Recommended

    Liquid error: Error in tag 'section' - 'anmegamenu-vert-1' is not a valid section type
    Liquid error: Error in tag 'section' - 'anmegamenu-vert-2' is not a valid section type
    Liquid error: Error in tag 'section' - 'anmegamenu-vert-3' is not a valid section type
    Liquid error: Error in tag 'section' - 'anmegamenu-vert-4' is not a valid section type
    Liquid error: Error in tag 'section' - 'anmegamenu-vert-5' is not a valid section type
    Liquid error: Error in tag 'section' - 'anmegamenu-vert-6' is not a valid section type
    Liquid error: Error in tag 'section' - 'anmegamenu-vert-7' is not a valid section type
    Liquid error: Error in tag 'section' - 'anmegamenu-vert-8' is not a valid section type
    Liquid error: Error in tag 'section' - 'anmegamenu-vert-9' is not a valid section type
    Liquid error: Error in tag 'section' - 'anmegamenu-vert-10' is not a valid section type

    This is a cookie agreement request — you can customize it or disable on the backoffice. Cookies help us to provide you the best experience using our website.

    Client service

    Have a question?
    You may contact us!

    OUR CONTACTS:
    +44 (0) 137 272 3434
    Mon-Fri: 9:00 am - 6:00 pm
    Sat: 9:00 am - 4:00 pm
    Sun: 9:00 am - 2:00 pm
    27 Oak Street, Tenafly, US, 07670
    Delivery:

    Free delivery on all orders in the UK

    PAYMENTS:

    Credit Card: Visa, MasterCard, Maestro, American Express

    RETUN POLICY:

    You can return any item purchased within 16 days of the delivery date

    Do you like any template? Apply its settings to your store — just select the template you like and press the «Apply» button of the desirable one. Templates can be switched at any time.
    Applying a new template overrides the settings. Press «Copy» and paste it into any text file to save your current settings.

    Export

    Import

    Import

    Newsletter

    Be the first to receive special offers, hear about our exclusive news and new product launches. We give 10% off your first order to every new subscriber. Join the TensCare family today.

    *By subscribing you agree to receive daily emails featuring news, promotional material and shopping offers from TensCare. You can change your preferences and unsubscribe at any time by clicking on the unsubscribe option in the email itself or in the email preference centre. Alternatively, press ESC or refresh the page to go directly to the site. View our Privacy & Cookie Policy here.