Shopping Bag
Free Royal Mail 2nd Class Delivery on all orders
Free Royal Mail 2nd Class Delivery on all orders
Free Royal Mail 2nd Class Delivery on all orders

Uniglo

Regular price

£170.00

From face to thighs, Uniglo the muscle stimulator has you covered. Designed for wrinkle reduction and muscle toning, this unit is a new take on improving one’s looks naturally. Instead of relying on EMS only, Uniglo incorporates microcurrent techn...
  • SKU:

Order by 3PM for NEXT DAY Delivery

UK only - T&C's apply for more details click here

We accept the following payment methods

master paypal visa klarna
Description

From face to thighs, Uniglo the muscle stimulator has you covered. Designed for wrinkle reduction and muscle toning, this unit is a new take on improving one’s looks naturally. Instead of relying on EMS only, Uniglo incorporates microcurrent technology, thus making it even more efficient.

The muscle stimulator can be used on multiple body parts to tone them: face, abs, buttocks and thighs, arms, calves and more. This is a great solution for those who want to get a face lift without an expensive and surgery as well as for those that simply want to add some firmness to their body.

Uniglo has a variety of preset programmes for different body parts, making it versatile and multi-purpose. A sleek design and a rechargeable battery also make this muscle stimulator flexible and travel-friendly, meaning you can always bring it with you anywhere.

As an addition, Uniglo has a memory function, making it easy to access the last programme used as well as track the overall usage of the device.

Warnings and Cautions

If you are in any doubt about any of these warnings please consult your medical adviser.

 

CONTRAINDICATIONS:

Do NOT use if you have a pacemaker (or if you have a heart rhythm problem) or with any electronic devices. Using this unit with electronic devices may cause erroneous operation of the device. Stimulation in the direct vicinity of an implanted device may affect some models.

Do NOT use during the first three months of pregnancy. It is not known whether TENS and EMS may affect foetal development.

Do NOT use on the abdomen in the later stages of pregnancy. Stop using immediately if you experience unexpected contractions.

 

WARNINGS:

Do NOT use when driving, operating machinery, or similar actions needing muscular control. Loose electrode pads, damaged leads, or sudden changes in contact may cause brief involuntary muscle movements.

Do NOT use to mask or relieve undiagnosed pain. This may delay diagnosis of a progressive condition.

Do NOT use if you have, in the area being treated: active or suspected cancer or undiagnosed pain with a history of cancer. Stimulation directly through a confirmed or suspected malignancy should be avoided as it may stimulate growth and promote spread of cancer cells.

Do NOT use electrodes near the thorax as this may increase the risk of cardiac fibrillation.

Do NOT use optional electrodes on the front of the neck. Stimulation on the front of the neck can affect your heart rate or cause contraction of the throat.

Do NOT use optional electrodes across the chest. Very strong 11 stimulation across the chest may cause an extra heartbeat. Do NOT use Uniglo while simultaneously connected to high frequency surgical equipment as it may result in burns at the site of stimulator electrodes and possible damage to the stimulator.

Do NOT use Uniglo in close proximity (e.g. 1 m) to a shortwave or microwave as this may produce instability in the stimulator output.

Do NOT use the FACE 1 or FACE 2 programmes if you have metal implants in the head or neck area.

Do NOT use the FACE 1 or FACE 2 programmes if you have Botox injections in the application area.

Do NOT use the FACE 1 or FACE 2 programmes for 6-8 weeks following collagen injections.

Do NOT use the FACE 1 or FACE 2 programmes for 1 year following a Retin A or Ro-Accuntaine treatment. This medication used in the treatment of acne can cause thinning of the skin.

Do NOT use any charger other than the one supplied. Use of other chargers could be hazardous.

Do NOT use the device whilst charging.

 

CAUTIONS:

Caution should be used if you have a bleeding disorder as stimulation may increase blood flow to the stimulated region.

Caution should be used if you have suspected or diagnosed epilepsy as electrical stimulation may affect seizure threshold.

Caution should be observed when using the device at the same time as being connected to monitoring equipment with body worn electrode pads. It may interfere with the signals being monitored.

Caution should be used following recent surgical procedures. Stimulation may disrupt the healing process.

Do not permit use by children unable to understand the instructions or persons with cognitive disabilities, i.e., Alzheimer’s disease or dementia.

Keep away from children under 5 years of age. Long cord - risk of strangulation in infants.

Caution should be observed when using the Uniglo at high strength settings. Prolonged use at high settings may cause muscle injury or tissue inflammation. The Uniglo is capable of delivering outputs in excess of 10 mA (RMS) or 10 V averaged over any period of 1 sec.

There are no user serviceable parts. No modification of this equipment is allowed.

 

DO NOT PLACE ELECTRODE PADS:

On skin, which does not have normal sensation. If the skin is numb too great a strength may be used, which could result in skin inflammation.

On broken skin. The electrode pads could encourage infection. • On the front of the neck. This could cause the airway to close, giving breathing problems. May cause sudden drop in blood pressure (vasovagal response).

Over the eyes. May affect eyesight or cause headaches.

Across the front of the head. Effect on patients who have had strokes or seizures is not known. May affect your sense of balance. The effects of stimulation on the brain are unknown.

 

ELECTRODE PADS CAUTION:

Do not ignore any allergic reaction to the electrode pads: If a skin irritation develops, stop using TENS, as this type of electrodes may not be suitable for you. Alternative electrode pads specially made for sensitive skin are available.

Do not use this device with leads or electrode pads other than those recommended by the manufacturer. Performance may vary from specification. Electrodes with smaller surface area may cause tissue irritation.

Electrode pads supplied have no measurable latex content.

 

TO KEEP YOUR DEVICE IN GOOD WORKING ORDER, OBSERVE THE FOLLOWING ADDITIONAL CAUTIONS:

Do not immerse your device in water or place it close to excessive heat such as a fireplace or radiant heater or sources of high humidity such as a nebulizer or kettle as this may cause it to cease to operate correctly.

Keep the device away from sunlight, as long-term exposure to sunlight may affect the rubber causing it to become less elastic and crack.

Keep the device away from lint and dust, as long-term exposure to lint or dust may affect the sockets or cause the battery connector to develop a bad contact.

Temperature & Relative Humidity of storage: -10°C to +45°C (≤ 3 months), 45% to 75% R.H. Temperature & Relative Humidity of transportation: -10°C to +60°C, 45% to 75% R.H.

Do not attempt to open or modify the unit. This may affect the safe operation of the unit and will invalidate the warranty.

There are no known side effects to use and long- 13 term use is not harmful. However, the device works your muscles and unaccustomed amounts of exercise may produce muscle ache. If this happens, simply reduce the strength of the machine, or allow your muscles to rest until the aching disappears.

Uniglo uses a combination of EMS and microcurrent technology.
Uniglo can be used on multiple body parts to improve their look.
Uniglo has 8 preset programmes for different body parts.

Key Features

8 preset programmes including a new Microcurrent deep facial toning programme;
Ergonomic and lightweight design enhances user experience;
Rechargeable battery;
New and improved detachable belt clip;
Memory function tracks device usage and last programme used;
Adjustable treatment timer.

What's Included

1 x Uniglo
2 x Lead wires
4 x 50x50mm electrode pads
4 x 30x50mm face electrode pads
10 x 25mm diameter circular electrode pads
1 x Charging adapter (UK/EU)
1 x Detachable belt clip
1 x Storage pouch
1 x Instructions manual

Customer Reviews

Come and Visit us in-store

Come visit
us in-store

Visit our office in Epsom, Surrey, UK. We would be delighted to welcome you!
Get Directions

View our
catalogue here

Give a look to all our devices and get a new level on pain relief, muscle toning and beauty enhancers with our clinically back-up units
Download Catalogue

Be the first to receive special offers, hear about our exclusive news and new product launches. We give 10% off your first order to every new subscriber. Join the TensCare family today.

Most Recommended

Most Recommended

Most Recommended

Most Recommended

Most Recommended

Liquid error: Error in tag 'section' - 'anmegamenu-vert-1' is not a valid section type
Liquid error: Error in tag 'section' - 'anmegamenu-vert-2' is not a valid section type
Liquid error: Error in tag 'section' - 'anmegamenu-vert-3' is not a valid section type
Liquid error: Error in tag 'section' - 'anmegamenu-vert-4' is not a valid section type
Liquid error: Error in tag 'section' - 'anmegamenu-vert-5' is not a valid section type
Liquid error: Error in tag 'section' - 'anmegamenu-vert-6' is not a valid section type
Liquid error: Error in tag 'section' - 'anmegamenu-vert-7' is not a valid section type
Liquid error: Error in tag 'section' - 'anmegamenu-vert-8' is not a valid section type
Liquid error: Error in tag 'section' - 'anmegamenu-vert-9' is not a valid section type
Liquid error: Error in tag 'section' - 'anmegamenu-vert-10' is not a valid section type

This is a cookie agreement request — you can customize it or disable on the backoffice. Cookies help us to provide you the best experience using our website.

Client service

Have a question?
You may contact us!

OUR CONTACTS:
+44 (0) 137 272 3434
Mon-Fri: 9:00 am - 6:00 pm
Sat: 9:00 am - 4:00 pm
Sun: 9:00 am - 2:00 pm
27 Oak Street, Tenafly, US, 07670
Delivery:

Free delivery on all orders in the UK

PAYMENTS:

Credit Card: Visa, MasterCard, Maestro, American Express

RETUN POLICY:

You can return any item purchased within 16 days of the delivery date

Do you like any template? Apply its settings to your store — just select the template you like and press the «Apply» button of the desirable one. Templates can be switched at any time.
Applying a new template overrides the settings. Press «Copy» and paste it into any text file to save your current settings.

Export

Import

Import

Newsletter

Be the first to receive special offers, hear about our exclusive news and new product launches. We give 10% off your first order to every new subscriber. Join the TensCare family today.

*By subscribing you agree to receive daily emails featuring news, promotional material and shopping offers from TensCare. You can change your preferences and unsubscribe at any time by clicking on the unsubscribe option in the email itself or in the email preference centre. Alternatively, press ESC or refresh the page to go directly to the site. View our Privacy & Cookie Policy here.